Outils pour utilisateurs

Outils du site


batterycapacitytester

Différences

Ci-dessous, les différences entre deux révisions de la page.

Lien vers cette vue comparative

batterycapacitytester [13/03/2025 00:20] – créée wikiadminbatterycapacitytester [13/03/2025 00:23] (Version actuelle) – [Key mapping] wikiadmin
Ligne 12: Ligne 12:
   * Coupure basse tension   * Coupure basse tension
  
-====== Utilisation ======+===== Utilisation =====
  
 {{ ::ccload_overview.jpg?400 |}} {{ ::ccload_overview.jpg?400 |}}
Ligne 22: Ligne 22:
 {{ ::ccload_panel.jpg?400 |}} {{ ::ccload_panel.jpg?400 |}}
  
-1: Up+  * 1: Up 
 +  * 2: Down - 
 +  * 3: move cursor 
 +  * 4: On/Off
  
-2: Down - +===== Setting current =====
- +
-3: move cursor +
- +
-4: On/Off +
- +
-==== Setting current ====+
  
 Set cursor by button "3" to position "I/V", select "I". Set cursor to numericals and alter values by buttons "1" / "2″. Set cursor by button "3" to position "I/V", select "I". Set cursor to numericals and alter values by buttons "1" / "2″.
  
-=== Setting voltage (lower voltage limit) ===+===== Setting voltage (lower voltage limit) =====
  
 Set cursor by button "3" to position "I/V", select "V". Set cursor to numericals and alter values by buttons "1" / "2″. Set cursor by button "3" to position "I/V", select "V". Set cursor to numericals and alter values by buttons "1" / "2″.
  
-== Switch load on/off ==+===== Switch load on/off =====
  
 Press button "4". Press button "4".
  
-== Reset values ==+===== Reset values =====
  
 Press and hold button "4". Press and hold button "4".
  
-== Select indicated values ==+===== Select indicated values =====
  
 Hold the button "3", at the same time press button "1" to select parameter. Button "2" resets display to "Auto", parameters are now displayed in sequence. Hold the button "3", at the same time press button "1" to select parameter. Button "2" resets display to "Auto", parameters are now displayed in sequence.
  
-== Buzzer on / off ==+===== Buzzer on / off =====
  
 Hold down button "3" while pressing button "4" at the same time to enable/disable the buzzer tone. Hold down button "3" while pressing button "4" at the same time to enable/disable the buzzer tone.
Ligne 57: Ligne 54:
 The setting shall be changed while having a load/battery connected. Press and hold button "3" until "Adjust mode" is shown on the display. Voltage then can be adjusted by buttons "1" and "2". Finally confirm with the button "4". The setting shall be changed while having a load/battery connected. Press and hold button "3" until "Adjust mode" is shown on the display. Voltage then can be adjusted by buttons "1" and "2". Finally confirm with the button "4".
  
-== Special functions ==+===== Special functions =====
  
 The following settings/functions are accessible by various key combinations when the device is powered on. The following settings/functions are accessible by various key combinations when the device is powered on.
  
-== Display the software version ==+===== Display the software version =====
  
 Hold buttons "1" and "2", connect the power supply. The version number - in this case "Edition 1.62", appears on the display. Hold buttons "1" and "2", connect the power supply. The version number - in this case "Edition 1.62", appears on the display.
  
-== Factory calibration ==+===== Factory calibration =====
  
 CAUTION! This mode can make the device unusable when done wrong. CAUTION! This mode can make the device unusable when done wrong.
batterycapacitytester.txt · Dernière modification : 13/03/2025 00:23 de wikiadmin